As-builts and Operations Manual

Posted on June 7, 2018 by Gsurface

14.6.1.1 A set of reproducible as-built installation drawings, operation and maintenance manuals, and a written sequence of operation shall be provided to the building owner or the owner’s designated representative.   Looking for our NICET Fire Alarm System Exam Study… Continue Reading →

General

Manual Pull Stations

Posted on June 6, 2018 by Gsurface

Saw this install at a project in a newly built warehouse. The blue colored pull station is there to release the standpipe solenoid. The standpipe is dry, not holding water, because it is installed in a huge freezer where if… Continue Reading →

General

Manual Fire Alarm Box

Posted on June 5, 2018 by Gsurface

The idea behind requiring a manual fire alarm box is to allow a means to initiate an alarm signal to Central Station in the event the fire detector or sprinkler water flow device is out of service or being tested.… Continue Reading →

General

Smoke Detector Installed on Peak Ceiling

Posted on June 4, 2018 by Gsurface

Below is an installation of a smoke detector on a peaked ceiling. NFPA 72 says that such detector shall be installed within 36 inches of the peak of the ceiling. 17.7.3.3* Peaked. Detectors shall first he spaced and located within… Continue Reading →

General

Air sampling smoke detection

Posted on June 3, 2018 by Gsurface

Here’s a video of a VESDA system at work. Some NFPA references about this installation. 17.7.3.6 Air Sampling~Type Smoke Detector. 17.7,3.6.1 Each sampling port of an air sampling-type smoke detector shall be treated as a spot-type detector for the pur-… Continue Reading →

General

Sprinkler Water Flow Device Activation

Posted on June 2, 2018 by Gsurface

Here we have a sprinkler water flow device activating at about 30 seconds. Here is a quote from the NFPA. Basically, activation of the fire alarm shall occur within 90 seconds of the flow of water. It shouldn’t occur immediately… Continue Reading →

General

Top of Elevator Shaft Smoke Detector

Posted on June 2, 2018 by Gsurface

A top of Elevator shaft smoke detector activating a fire smoke damper. Chapter 6 Protected Premises Fire Alarm Systems. 6.15.3 Elevator Recall for Fire Fighter’s Service. 6.15.3.6 Smoke Detectors shall not be installed in un-sprinklered elevator hoistways unless they are installed… Continue Reading →

General

Why get NICET Fire Alarms Certified?

Posted on August 9, 2016 by Gsurface

NICET affirmations depend on the competitor’s capacity to demonstrate a level of mastery in their field by means of an examination, work experience, and execution check. Fluctuating levels of accreditation speak to various levels of mastery in your field, with… Continue Reading →

General

NICET Fire Alarm Systems Level 2 Study Guide

Posted on August 3, 2016 by Gsurface

Level II (2) Study Guide is here…..Available Now @Amazon Congratulations on passing Level 1. Now, it is time for Level 2. Similar to the Level 1 guide, the purpose of this book is to prepare those interested in taking the… Continue Reading →

General

NICET Fire Alarm System Level I Pop Quiz #10

Posted on March 1, 2016 by Gsurface

According to NFPA 72, the mounting height of a strobe light is between ___________ inches and __________ inches above finished floor.

Pop Quiz

Post navigation

Older Articles
Newer Articles
Follow on Instagram
This error message is only visible to WordPress admins

Error: No posts found.

Make sure this account has posts available on instagram.com.

Recent Posts

  • An Introduction to Fire Alarm Systems
  • NICET Fire Alarm Systems Levels 1 & 2 Study Guide
  • 2018 NICET Fire Alarm Systems Level 2 Study Guide
  • 2018 NICET Fire Alarm Systems Level 1 Study Guide
  • NICET Certification Fire Alarm System Pop Quiz Question-Concealed Duct Detector

Recent Comments

    Archives

    • February 2020
    • July 2019
    • June 2019
    • October 2018
    • September 2018
    • July 2018
    • June 2018
    • August 2016
    • March 2016
    • February 2016
    • January 2016
    • December 2015

    Meta

    • Register
    • Log in
    • Entries feed
    • Comments feed
    • WordPress.org

    Categories

    • General
    • News
    • Pop Quiz
    • Videos
    © 2025 Fire Alarms Certified. All rights reserved.
    Hiero by aThemes