Fire Alarms Certified
Menu Close
  • Home
  • Instructor Resources
  • NICET Fire Alarm Systems Level 1 Exam Study Guide
  • NICET Fire Alarm Systems Level 2 Study Guide
  • The Value and Importance of NICET Fire Alarm Certification
  • About
  • Contact and Other Info

Pop Quiz

NICET Certification Fire Alarm System Pop Quiz Question-Concealed Duct Detector

Posted on July 10, 2018 by Gsurface

Below we have another sample NICET certification fire alarm system question to help you prep for the actual exam: Question: Where smoke detectors are installed in concealed locations more than ____ above the finished floor or in arrangements where the… Continue Reading →

Pop Quiz

NICET Certification Fire Alarm System Pop Quiz Question

Posted on July 7, 2018 by Gsurface

Below is another pop quiz question to help you prep for the NICET Certification Fire Alarm System exam.  Feel free to browse other questions here. Question: A speaker/strobe (alarm notification appliance) was installed in a gymnasium of a school.  The… Continue Reading →

Pop Quiz

NICET Certification Fire Alarm System Pop Quiz Question

Posted on July 6, 2018 by Gsurface

While working on a Large Group B building I encountered a number of devices (smoke detectors) with dust/debris covers.  Below is a question to help you prepare for the actual NICET certification Fire Alarm Systems exam.  Feel free to comment… Continue Reading →

Pop Quiz

NICET Certification – Fire Alarm System Pop Quiz Question: Remote annunciators shall be ____________?

Posted on July 4, 2018 by Gsurface
remote annunciator

Remote annunciators shall be ______________? (a) painted red and mounted at least 42 inches above grade. (b) painted red and locked. (c)  be installed readily accessible to responding personnel (d) be installed accessible to building personnel.. To find the answer… Continue Reading →

Pop Quiz

NICET Fire Alarm System Level I Pop Quiz #10

Posted on March 1, 2016 by Gsurface

According to NFPA 72, the mounting height of a strobe light is between ___________ inches and __________ inches above finished floor.

Pop Quiz

NICET Level I Fire Alarm Systems Pop Quiz #9

Posted on February 4, 2016 by Gsurface

What is the color code requirement for a spot-type heat detector rated at 200 degrees Fahrenheit? a. White b. Blue c. Red d. Green Share your answer by commenting.

Pop Quiz

NICET Level I Fire Alarm Systems Pop Quiz #8

Posted on February 1, 2016 by Gsurface

Unless otherwise required by the AHJ, only the elevator lobby, elevator hoistway, and elevator machine room smoke detectors, or other automatic fire detection, shall be used to________________________. a.  Send a specific and coded signal to the FACP. b.  Recall elevators… Continue Reading →

Pop Quiz

NICET Level I Fire Alarm Systems Pop Quiz #7

Posted on January 18, 2016 by Gsurface

Monitoring for integrity shall not be required for the interconnection between listed equipment within __________________. a. the same building. b. the same zone. c. a common enclosure. d. the same floor.  

Pop Quiz

NICET Level I Fire Alarm Systems Pop Quiz #6

Posted on January 8, 2016 by Gsurface

The secondary power supply shall automatically provide power to the protected premises system within __________ whenever the primary power fails. a. 5 seconds b. 10 seconds c. 60 seconds d. 90 seconds Please comment to share your answer and include… Continue Reading →

Pop Quiz

NICET Level I Fire Alarm Systems Pop Quiz #5

Posted on January 6, 2016 by Gsurface

Fire alarm cables were installed using RMC. What must be installed/provided when the conduit is terminated at boxes, fittings and or other enclosures? a. Conduit support straps within 1 foot of where the conduit terminates. b. Expansion fittings for the… Continue Reading →

Pop Quiz

Post navigation

Older Articles
Follow on Instagram
This error message is only visible to WordPress admins

Error: No posts found.

Make sure this account has posts available on instagram.com.

Recent Posts

  • An Introduction to Fire Alarm Systems
  • NICET Fire Alarm Systems Levels 1 & 2 Study Guide
  • 2018 NICET Fire Alarm Systems Level 2 Study Guide
  • 2018 NICET Fire Alarm Systems Level 1 Study Guide
  • NICET Certification Fire Alarm System Pop Quiz Question-Concealed Duct Detector

Recent Comments

    Archives

    • February 2020
    • July 2019
    • June 2019
    • October 2018
    • September 2018
    • July 2018
    • June 2018
    • August 2016
    • March 2016
    • February 2016
    • January 2016
    • December 2015

    Meta

    • Register
    • Log in
    • Entries feed
    • Comments feed
    • WordPress.org

    Categories

    • General
    • News
    • Pop Quiz
    • Videos
    © 2025 Fire Alarms Certified. All rights reserved.
    Hiero by aThemes